Tabelka poniżej prezentuje parametry techniczne urządzenia. W przypadku, gdyby prezentowane w niej informacje były niekompletne lub budziły wątpliwości prosimy o kontakt mailem bądź telefonicznie z naszym działem technicznym. Dodatkowo służymy pomocą w doborze właściwego urządzenia tak, aby optymalnie spełniało wymagania Państwa projektu.
| Product
specification |
| Product Description |
| Model | KIEN2000-2M |
| Description | Unmanaged Industrial Ethernet Rail Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) |
| Port Type and Quantity | 2 x 100Base-FX, optical fiber cable, redundant, duplex 6 x 10 /100Base-T/TX, TP cable, RJ45 Socket (shielded), auto-negotiation, auto-polarity |
| More Interface |
| Power Terminal | 2 x DC power terminal, 3-core |
| Alarm Terminal | 1 x alarm output terminal, 2-core |
| Network size-length of cable |
| Twisted pair (TP) | 100m |
| Singlemode fiber | Distance: 40km(60km, 80km for special requirement) Wavelength: 1310/1550nm Optical power: >-13dbm |
| Multimode fiber | Distance: 2-5km Wavelength: 1310nm Optical power: >-20dbm |
| Network size - cascadibility |
| Line - / star topology | Any |
| Ring structure (DT-Ring) | 50 switches (recovery time < 300ms) |
| Power requirements |
| Power input | 18V - 36V DC power input |
| Power consumption | «6W |
| Performance |
| Transfer Rate | 148810pps |
| MAC Address Table Size | 1K |
| Service |
| Diagnostics | LEDs (power, link status, port rate), fault relais (24VDC/1A) |
| Redundancy |
| Redundancy functions | DT-Ring (ring structure), redundant 24V power supply |
| Ambient conditions |
| Operating temperature | -35°C to +75°C |
| Storage/transport temperature | -45°C to +85°C |
| Relative humidity (non-condensing) | 10% to 95% |
| MTBF | 10 years |
| Mechanical construction |
| Dimensions (W x H x D) | 55.4mm x 142mm x 120.5mm |
| Mounting | DIN-Rail or Wall mounting |
| Protection class | IP40 |
| EMC interference immunity |
| EN 61000-4-2 electrostatic discharge (ESD) | +4 kV contact discharge, +8 kV air discharge |
| EN 61000-4-3 electromagnetic field | 10 V/m (80 - 1000 MHz) |
| EN 61000-4-4 fast transients (burst) | +2 KV power line, +1 kV data line |
| EN 61000-4-5 surge voltage | Power line: +2 kV (line/earth), +1 kV (line/line), +1 kV data line |
| EN 61000-4-6 conducted immunity | 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80MHz) |
| EMC emitted immunity |
| FCC CFR47 Part 15 | FCC CFR47 Part 15 Class A |
| EN 55022 | EN 55022 Class A |
| Approvals |
| Certificate | FCC, CE, UL |